Modbus Simulator

A simple modbus/tcp server based on the modbus server implementation from github.com/tbrandon/mbserver

The Holding Registers and Input Registers are defined as follows:

Holding Registers

To read Holding Register 100 use 400100

Address Description
100 0xff00 ie. 65280
101 0xffff ie. 65535 or -1
102 0x0000 ie. 0
201 artificially generates error: IllegalFunction
202 artificially generates error: IllegalDataAddress
203 artificially generates error: IllegalDataValue
204 artificially generates error: SlaveDeviceFailure
205 artificially generates error: AcknowledgeSlave
206 artificially generates error: SlaveDeviceBusy
207 artificially generates error: NegativeAcknowledge
208 artificially generates error: MemoryParityError
210 artificially generates error: GatewayPathUnavailable
211 artificially generates error: GatewayTargetDeviceFailedtoRespond
300 uptime msb
301 uptime lsb
302 application start time msb
303 application start time lsb
400 unixtime msb
401 unixtime lsb
500 math.pi msb
501 math.pi lsb

Input Registers

To read Input Register 100 use 300100

Address Description
100 0xff00 ie. 65280
101 0xffff ie. 65535 or -1
102 0x0000 ie. 0
201 artificially generates error: IllegalFunction
202 artificially generates error: IllegalDataAddress
203 artificially generates error: IllegalDataValue
204 artificially generates error: SlaveDeviceFailure
205 artificially generates error: AcknowledgeSlave
206 artificially generates error: SlaveDeviceBusy
207 artificially generates error: NegativeAcknowledge
208 artificially generates error: MemoryParityError
210 artificially generates error: GatewayPathUnavailable
211 artificially generates error: GatewayTargetDeviceFailedtoRespond
300 uptime msb
301 uptime lsb
302 application start time msb
303 application start time lsb
400 unixtime msb
401 unixtime lsb
500 math.pi msb
501 math.pi lsb

Supported Architectures

Simply pulling techplex/modbus-sim:latest should retrieve the correct image for your arch.

The architectures supported by this image are:

Architecture Available
x86-64
arm64
armhf

Application Setup

The application can be accessed at tcp://yourhost:1502

Usage

Here are some example snippets to help you get started creating a container.

docker-compose

---
version: "2.1"
services:
  modbus:
    image: techplex/modbus-sim:latest
    container_name: modbus
    ports:
      - 1502:1502
    restart: unless-stopped

docker cli

docker run -d \
  --name=modbus \
  -p 1502:1502 \
  --restart unless-stopped \
  techplex/modbus-sim:latest

Updating Info

Below are the instructions for updating containers:

Via Docker Compose

  • Update all images: docker-compose pull
    • or update a single image: docker-compose pull techplex/modbus-sim
  • Let compose update all containers as necessary: docker-compose up -d
    • or update a single container: docker-compose up -d techplex/modbus-sim
  • You can also remove the old dangling images: docker image prune

Via Docker Run

  • Update the image: docker pull techplex/modbus-sim:latest
  • Stop the running container: docker stop techplex/modbus-sim
  • Delete the container: docker rm techplex/modbus-sim
  • Recreate a new container with the same docker run parameters as instructed above
  • You can also remove the old dangling images: docker image prune

Building locally

If you want to make local modifications to these images for development purposes or just to customize the logic:

git clone https://github.com/techplexengineer/modbus-sim.git
cd modbus-sim
docker build \
  --no-cache \
  --pull \
  -t techplex/modbus-sim:latest .

GitHub